Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| After-sales Service: | Online Video Service |
| Warranty: | One Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

| Model | M300F | |
| Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
pH |
Range | -2.00 to 20.00pH |
| Resolution | 0.1, 0.01 pH | |
| Accuracy | ± 0.01 pH | |
| Calibration Points | Up to 5 | |
| Standard Customization | Yes | |
| Standard Recognition | NIST, GB and DIN buffers | |
| Slope Limit | Yes | |
| mV | Range | -2000.0 to 2000.0 mV |
| Resolution | 0.1 mV | |
| Accuracy | ± 0.3 mV or ± 0. 1% | |
pX |
Range | -2.00 to 20.00 |
| Resolution | 0.1, 0.01 pX | |
| Accuracy | ± 0.01 pX | |
| Calibration Points | Up to 5 | |
ISE |
Range | 1E-9 to 9.999E9 |
| Unit | mol/L, mmol/L, g/L, mg/L, μ g/L, ppm | |
| Resolution | Up to 4 significant digits | |
| Accuracy | ± 0.5% | |
| Calibration Points | Up to 5 | |
Conductivity |
Range | 0.000 μ S/cm to 1000 mS/cm |
| Resolution | 0.001 μ S/cm minimum, various with range selection |
|
| Accuracy | ± 1.0% FS | |
| Reference Temperature | 20, 25 ºC | |
| Calibration Points | Up to 3 | |
| Standard Recognition | 84 μ S/cm, 1413 μ S/cm, 12.88mS/cm | |
| Resistivity | Range | 5.00 Ω ·cm~20.00 M Ω ·cm |
| Resolution | 0.01 Ω ·cm minimum | |
| Accuracy | ± 1.0% FS | |
| TDS | Range | 0.00mg/L~300g/L |
| Resolution | 0.01mg/L minimum, various with range selection | |
| Accuracy | ± 1.0% FS | |
| Salinity | Range | (0.00~8.00)% |
| Resolution | 0.01% | |
| Accuracy | ± 0.2% | |
Dissolved Oxygen Con- centration |
Range | 0.00 to 20.00 mg/L |
| Resolution | 0.01mg/L | |
| Accuracy | ± 0. 1mg/L | |
| Calibration Points | Air-saturated water or zero point | |
| Barometric Compensation | Yes | |
| Manual Salinity Factor Correction | Yes | |
| Saturation | Range | (0.0 to 200.0)% |
| Resolution | 0.1% | |
| Accuracy | ± 2.0% | |
Temperature |
Range | -5 to 110 ºC, 23 to 230 ºF |
| Unit | ºC, ºF | |
| Resolution | 0.1 | |
| Accuracy | ± 0.2 | |
| Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
| Reading Prompts | Reading, Stable, Locked | |
| Temp. Compensation | ATC, MTC | |
| Data manage- ment | Data Storage | 500 results each |
| GLP Features | Yes | |
| Inputs | pH Electrode | BNC(Q9) |
| DO with Temp. Probe | 4-pin aviation connector | |
| Conductivity with Temp. Probe | 5-pin aviation connector | |
| Outputs | USB | USB 2.0 flash memory device, PC |
| RS 232 | printer | |
| Display op- tions | Backlight | Yes |
| Auto Shutdown | 1~60 min, off | |
| IP Rating | IP54 | |
| Date and Time | Yes | |
| General | Power | AC Adapter, 100-240V AC input, DC9V output |
| Dimensions | 242 × 195 × 68 mm | |
| Weight | 900g (1.98 lb) | |

Q1: Are you trading company or manufacturer ?