C18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC Column

Product Details
Customization: Available
After-sales Service: Online Video Service
Warranty: One Year
Still deciding? Get samples of US$ 430/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (14)
  • C18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC Column
  • C18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC Column
  • C18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC Column
  • C18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC Column
  • C18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC Column
  • C18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC Column
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Product Features
  • Detailed Photos
  • Company Profile
  • Our factory
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
AY-AQ-C18
Appliance
Medical Research
Certification
CE, GMP
Stationary Phase
Solid Adsorbent
Mobile Phase
Liquid
Chromatography Type
Liquid Chromatography
Chromatographic Column Type
Convetional Analytical Column
Chromatographic Column Length
10~30cm
Chromatographic Column Diameter
2~5mm
USP Ref.
L1
Pore Size
120A
Particle Size
5um
Surface Area
320 M2/G
pH Range
2-8
Transport Package
Cartons
Specification
5um*4.6mm*100mm
Trademark
AIYI
Origin
China
HS Code
9027900000
Production Capacity
100 Sets/Month

Packaging & Delivery

Package Size
29.00cm * 10.00cm * 5.00cm
Package Gross Weight
0.500kg

Product Description

c18 reverse phase chromatography column 5um*4.6mm*100mm nucleosil c18 rp hplc column
Product Description

 

hplc column selection
1. Column tube specifications: including column length and inner diameter, common specifications include 150mm x 4.6mm. The longer the column length, the better the separation effect, but it will increase the column pressure and analysis time. A shorter column length (such as 50mm) is usually sufficient to provide good separation efficiency.
2. Particle size: Particle size affects separation speed and column efficiency. Smaller particle sizes (such as 1.8 μ m, 3.5 μ m) can provide higher column efficiency, but require higher column pressure. 5 μ m filler is a commonly used choice for analysis.
3. Pore size: Pore size affects the retention characteristics of the sample, and common pore sizes include 60 Å, 120 Å, and 300 Å. Small molecules are suitable for pore sizes of 80-120 Å, while large molecules are suitable for pore sizes of 300 Å.
4. Shape of packing particles: Spherical particles can reduce column pressure and prolong column life in high viscosity mobile phases.
5. Specific surface area: Specific surface area is related to particle size and pore size, which affects the contact area between the sample and the filler, thereby affecting the separation effect.
6. Chemical properties: including silicone matrix, polymer matrix, carbon loading, bonding phase, and end capping. Different chemical properties affect the separation selectivity and stability of chromatographic columns.
7. pH Range: The pH range of a chromatographic column affects its performance under specific conditions.
8. Column efficiency: It is usually measured by the theoretical number of trays and is an important indicator for evaluating the efficiency of chromatographic columns.
9. Separation degree: Separation degree is an indicator of the separation performance of a chromatographic column.
10. Peak symmetry: Peak symmetry is an indicator that describes the degree of symmetry of chromatographic peaks, and a symmetrical peak shape helps improve the accuracy of analysis.

*Tell us your requirements, and we will select the most suitable chromatographic column for you
Product Parameters

 

HPLC Columns
Specifications
USP Ref.
Particle size (um)
Pore Size(A)
Surface
Area(m2/g)
C%
pH Range
Endcapped
C18-Aqueous
L1
3,5,10
120
320
12%
1.5-10
Y
C18-Universal
L1
1.8.3,5,10
120
320
17%
1.5-10
Y
300
90
8%
C18-Low pH
L1
5
130
160
10%
2.0-8.0
N
C18-Alkaline
L1
3,5,10
120
320
17%
1.5-10
N
C8-Universal
L7
1.8,3,5,10
120
320
12%
1.5-10
Y
300
90
C8-Low pH
L7
5
120
320
5.50%
1.0-8.0
N
C8-Fluorine
L7
5
120
320
12%
1.5-10
Y
C1
L13
5
120
320
4%
1.5-10
Y
C4
L26
3.5
120
320
8%
1.5-10
Y
300
90
3%
SiO2
L3
5
120
320
N/A
1.5-10
N
NH2
L8
5
120
320
N/A
1.5-10
N
CN
L10
5
120
320
6%
1.5-10
N
Phenyl
L11
3,5.10
120
320
12%
1.5-10
Y
300
90
6%
Phenyl-Ether
/
5
120
320
12%
1.5-10
Y
Polar RP
L1
1.8,3,5,10
120
320
18%
1.5-10
Y
300
90
SCX
/
5
120
320
N/A
2.0-8.0
N
SAX
/
5
120
320
7.50%
2.0-8.0
N
Diol
/
5
120
320
2.50%
1.5-10
N
C30
L62
5
120
320
17%
1.5-10
Y
Amino Acid
/
3, 5
120
320
17%
1.5-10
Y
PAH
/
5
120
320
22%
1.5-10
Y
PFP
/
5
120
320
13%
1.5-10
Y
HILIC Amide
/
5
120
320
7%
2.0-8.0
N
C18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC ColumnC18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC Column
Product Features

 

1.Proprietary surface modification for smooth, uniform and inert silica surface.
2.Long column lifetime and more injections.
3.Unique bonding chemistry and end-capping technology.
4.Exceptional lot-to-lot reproducibility.
5.Excellent peak shape, especially for polar, acidic and basic compounds.
6.Available in analytical and prep types, of all dimensions and sample sizes.
7.Series of stationary reversed phase and normal phases for wide selectivity.
8.Best value - high premium products with very competitive price.
Detailed Photos

 

C18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC ColumnC18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC Column
C18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC ColumnC18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC Column
Company Profile

C18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC ColumnJiangxi AIYI Hi-Tech Co., Ltd. was founded in 2015 and is located in the scenic Nanchang Hi-Tech Industrial Development Zone. We specialize in providing high-quality laboratory equipment and extensive technical support worldwide.

 
Our main products cover five core areas: chromatograph, spectrometers, general-purpose instruments, laboratory furniture and life science instruments. Chromatograph and spectrometers, such as High Performance Liquid Chromatograph (HPLC), Atomic Absorption Spectrometer (AAS), Inductively Coupled Plasma Emission Spectrometer (ICP-OES), etc., are unique in the environmental monitoring and material science industries due to their excellent analytical capabilities and stability. General-purpose instruments, including high-precision pipettes, thermostats, etc., ensure that every experimental operation can achieve the perfect combination of precision and efficiency. Laboratory furniture, incorporating modern design concepts and safety standards, provides researchers with an aesthetically pleasing as well as practical working environment. Life science instruments, such as PCR instruments and gel imaging analyzers, help the cutting-edge research in the field of life science.
Our factory
C18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC Column
C18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC Column
Packaging & Shipping

C18 Reverse Phase Chromatography Column 5um*4.6mm*100mm Nucleosil C18 RP HPLC Column


No accident shipping term:
DHL: 5-7 working days;
UPS: 7-9 working days;
FedEx: 7-9 working days;
EMS: 25-30 working days;
China Post: Depends on ship to which country;
Sea: Depends on ship to which country
FAQ

 

1. Are the columns compatible with my existing chromatography system and detectors?
Our columns are designed with a variety of interface types to ensure compatibility with most chromatography systems and detectors. If you provide us with the specific model number of your existing system, we can recommend the most suitable column model.

2. What is the separation efficiency of the column? How high resolution and selectivity can it achieve?
Our columns use advanced packing technology and unique stationary phase chemistry to ensure high separation efficiency and resolution. We can provide customized columns according to the type of sample you need to analyze and the separation requirements.

3. What are the stationary phase and carrier materials for the columns?
Our columns are made of high quality materials with excellent chemical stability and durability. Whether it is polar or non-polar samples, we have the appropriate column products to meet the analytical needs of different chemical properties.

4. Are the column dimensions (length, inner diameter) and particle size specifications suitable for my analytical needs?
We offer a wide range of column sizes and specifications to suit different analytical methods and sample volumes. You can choose the appropriate column length, inner diameter and particle size according to your analytical needs to achieve the best separation effect.

5. Do you offer cost-effective options, including running cost and lifetime?
Our columns strive to offer competitive pricing while maintaining performance. We focus on long-term customer relationships, so we offer cost-effective products that take into account running costs and column lifetime to ensure that you get cost-effective results over the long term.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier