• Flame and Graphite Furnace Semi Atomic Absorption Spectrophotometer Aas for Food/Metal Analysis
  • Flame and Graphite Furnace Semi Atomic Absorption Spectrophotometer Aas for Food/Metal Analysis
  • Flame and Graphite Furnace Semi Atomic Absorption Spectrophotometer Aas for Food/Metal Analysis
  • Flame and Graphite Furnace Semi Atomic Absorption Spectrophotometer Aas for Food/Metal Analysis
  • Flame and Graphite Furnace Semi Atomic Absorption Spectrophotometer Aas for Food/Metal Analysis

Flame and Graphite Furnace Semi Atomic Absorption Spectrophotometer Aas for Food/Metal Analysis

After-sales Service: Online Video Service
Application: Laboratory Apparatus
Warranty: 1 Year
Detection Method: Spectrophotometer
Advantage: High Sensitive
Principle: Classic Spectrometer
Samples:
US$ 10799/Set 1 Set(Min.Order)
| Request Sample
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Trading Company
  • Overview
  • Packaging & Shipping
  • Company Profile
  • Certifications
Overview

Basic Info.

Model NO.
AYAA 2000FG
Wavelengths
185-910nm
Dispersive Element
Grating Spectrometer
Certification
ISO9001
Customized
Customized
Grating Line Density
1800 Line/mm
Lampholder
8 Lampholders
Wavelength Accuracy
±0.10nm
Wavelength Repeatability
0.05nm
Baseline Drift
Static: 0.002A/30min
Detector
Wide Spectral Range Pmt
Power Supply
AC 220V/50Hz 150va (Spectrometer)
Transport Package
Cartons
Specification
135*60*85cm
Trademark
AIYI
Origin
China
HS Code
9027300090
Production Capacity
5 Sets/Month

Product Description

Flame And Graphite Furnace Semi Atomic Absorption Spectrophotometer AAS For Food/Metal Analysis

 
Flame and Graphite Furnace Semi Atomic Absorption Spectrophotometer Aas for Food/Metal Analysis
Feature
I.It has both flame and graphite furnace atomizers. The two test modes can be automatically switched and automatically matched.
II.Modular design, users can flexibly configure or upgrade according to needs
III.Fully automatic 8-position rotating lighthouse, automatic switching, free setting of work light/preheating light
IV.Total reflection optical system, full-band achromatic, automatic wavelength scanning, automatic peak search
V.Both flame and graphite furnace systems have deu.terium lamps and self-priming background subtraction to meet the detection needs of complex matrix samples.
VI.Full titanium burner, stable combustion and fast heat balance
VII.Graphite furnace constant power temperature control achieves uniform graphite tube temperature
VIII.Reliable multiple protection system, real-time flame monitoring, acetylene leakage monitoring and protection, real-time monitoring of abnormal pressure, cooling water monitoring
IX.Powerful operating software and simple human-computer interaction design meet the regulatory requirements of 21CFR part11, authority management, and audit tracking.
Flame and Graphite Furnace Semi Atomic Absorption Spectrophotometer Aas for Food/Metal Analysis
Flame and Graphite Furnace Semi Atomic Absorption Spectrophotometer Aas for Food/Metal Analysis


Flame and Graphite Furnace Semi Atomic Absorption Spectrophotometer Aas for Food/Metal Analysis
Specification
AYAA 2000FG
Power
AC 220V/50Hz 150VA (Spectrometer)
Net weight
55kg (Spectrometer)
Gross weight
80kg (Spectrometer)
Instrument size
1110mm(L) × 400mm(W) × 500mm(H) (Spectrometer)
Pack size
1350mm(L) × 600mm(W) × 850mm(H) (Spectrometer)
Working temperature
10~35ºC
Working humidity
≤80%
 
1.Optical system
Wavelength range
185nm~910nm auto scan
Grating groove
1800 line/mm
Monochromator
Czerny-Turner type
Spectral bandwidth
0.1,0.2,0.4,1.0,2.0nm, auto switch
Wavelength accuracy
±0.10nm
Wavelength repeatability
0.05nm
Baseline drift
Static: 0.002A/30min
Detector
Wide spectral range PMT
Spectral resolution
≤0.3nm
2.Light source(Hollow Cathode Lamp)
HCL base
Rotary automatic eight slots
Set individually position for specific element lamp.
Freely set the work light and preheating lamp to maximize the preparation time of the element lamp.
HCL Power supply
Pulse modulated constant current drive
HCL Current range
0~10mA average current
3.Atomizer
Flame atomizer(De.uterium arc background corrector)
Detection limit (Cu)
0.003μg/ml
Burner
100mm titanium burner
Precision
RSD≤0.5%(Cu)
Sprayer
High-efficiency metal and glass sprayer
Atomizer chamber
Corrosion resisting plastic chamber
Safety measure
Auto protective, acetylene leak detection and auto switch off
Flame free(graphite furnace) analysis method
Detection limit (Cd)
≤0.3×10-12g
Accuracy
RSD≤2%(Cd,Cu)
Heating temperature range
RT~3000ºC
4. Flame atomizer analysis
Method
Air-acetylene flame
Concentration calculation
Standard curve, standard addition, interpolation
Repeat times
1~99 times,auto calculation of average, concentration, standard deviation, RSD
Result print
Print test data or final analysis report,or results can be Excel.
Operating system
Windows 10
5. Flame free analysis method
Measuring method
Peak height and peak area method
Heating method
Advanced vertical constant power graphite furnance
Background correction
Self-reversal deducting background ≥60 times@1Abs Deu.terium arc background corrector ≥60 times@1Abs
Repeating measurements
1-30 times, calculate the average, and give the standard deviation and relative standard deviation
Print results
Print test data or final analysis report,or results can be Excel.
Software environment
Windows10 operating system, professional software.

Standard configuration
1. Atomic absorption spectrometer
2. Low noise oil free air compressor
3. Hollow cathode lamp (HCL)
4. Operating software
Packaging & Shipping

Flame and Graphite Furnace Semi Atomic Absorption Spectrophotometer Aas for Food/Metal Analysis

Company Profile

Flame and Graphite Furnace Semi Atomic Absorption Spectrophotometer Aas for Food/Metal AnalysisFounded in 2015, Jiangxi Aiyi High Tech Co., Ltd . is located in Nanchang, a beautiful hero city. It is a professional company integrated R&D, design, manufacturing and sales of a full range of laboratory instruments and consumables. Aiyi is a one-stop supplier and service provider of laboratory instruments and laboratory consumables. The company's main business varieties are: laboratory basic equipment, analytical instruments, optical instruments, environmental protection equipment, electronic equipment, medical equipment. The company's products are widely used at home and abroad: colleges and universities, research institutes, chemical, pharmaceutical, environmental protection, petroleum, food, light industry and other fields. Provide them with advanced equipment and technical support.
 

Certifications

Flame and Graphite Furnace Semi Atomic Absorption Spectrophotometer Aas for Food/Metal Analysis

No accident shipping term:
DHL: 5-7 working days;
UPS: 7-9 working days;
FedEx: 7-9 working days;
EMS: 25-30 working days;
China Post: Depends on ship to which country;
Sea: Depends on ship to which country
Flame and Graphite Furnace Semi Atomic Absorption Spectrophotometer Aas for Food/Metal AnalysisQ1: Are you trading company or manufacturer ?
A: We are manufacturer and do both OEM and ODM. We have our own R&D team.
Q2: How to order?
A: Send inquiries → Reply you quotations → Discuss details → Confirm samples → 
Deposit → Mass production → Cargo ready → Balance/Delivery → More cooperations.
Q3: What is your payment method ?
A: We accept T/T, Western Union, Paypal and MoneyGram, those depend on specific cases.
Q4: How long is your delivery time?
A: Usually 1-3 working days for products in stock. If we do special offer, it usually takes 
4-6 weeks. Also delivery time is according to your quantity of order.
Q5: How to transport?
A: DHL, UPS, FedEx, TNT, EMS, China Post and Sea are available.Also other shipping ways are 
available. Please feel free to contact us for other shipping ways.
Q6: How is your warranty service?
A: We do strict test before shipping and guarantee for 365 days. If quality problem you 
could send us pictures or video clips about problem. Then we deal with the problem ASAP.
Flame and Graphite Furnace Semi Atomic Absorption Spectrophotometer Aas for Food/Metal Analysis

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now