• Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume Gcms
  • Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume Gcms
  • Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume Gcms
  • Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume Gcms
  • Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume Gcms
  • Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume Gcms

Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume Gcms

After-sales Service: Online Video Service
Application: Laboratory Apparatus
Warranty: 1 Year
Samples:
US$ 79999/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume Gcms pictures & photos
Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume Gcms
US $77,885 / Piece
Min. Order: 1 Piece
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Trading Company

Basic Info.

Model NO.
GC91MS10
Detection Method
Spectroscopic
Advantage
High Sensitive
Principle
Mass Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
CE
Transport Package
Carton
Specification
160*64*58cm
Trademark
AIYI
Origin
China
HS Code
9027812000
Production Capacity
10 Sets/Month

Product Description

Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume GCMS
Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume Gcms
Technical Features

1. A full set of electronic automatic flow control
1.1 The gas chromatograph of Pannuo Instrument is equipped with fully imported automatic gas flow control modules in the inlet, detector and auxiliary gas, so as to achieve the best separation effect, improve the analysis efficiency, and ensure good accuracy and repeatability.
1.2 There is no need to manually adjust and measure the flow and pressure of each module one by one. All parameters can be directly input and saved in the operating software as required. The saved method parameters can be called and optimized at any time. It is efficient, accurate, simple, convenient and easy to operate. It greatly reduces the daily work and difficulty of operators.
1.3 Temperature compensation ensures accurate flow and pressure. There is no need to worry about whether the set parameters are offset or the accuracy of the gas flow is measured regularly. It is convenient for the operator to perform accurate qualitative and quantitative analysis of the target, and reduce the misjudgment of the detection results.
1.4 The constant flow control mode of the chromatographic column reduces the decrease of the column flow rate caused by the temperature program, which greatly improves the column efficiency, improves the peak shape and separation effect, and reduces the analysis time.
1.5 Through automatic information feedback, if hydrogen leaks or other gas circuits are under pressure, the instrument will automatically alarm, and if the fault cannot be eliminated within a short time, the instrument will automatically shut down the gas circuit and all heating modules, and automatically protect to prevent air burning from damaging the detector chromatogram Accidents caused by important components such as columns or hydrogen leakage.
1.6 The networked data communication and remote control system adopts the advanced and convenient 100M Ethernet communication interface, which can realize the remote measurement and control of the instrument's operating parameters (temperature, flow and various detector operating parameters) and fault self-diagnosis.
1.7 Industry-leading mass detector design
1.7.1 Built-in UPS (protection against power failure)
1.7.2 The modular electronic device design of the motherboard is interchangeable, which facilitates early fault judgment and effectively reduces maintenance costs
1.7.3 The inert isothermal ceramic ion source has strong anti-pollution ability. The front panel of the ion source is removable, and the filament can be replaced without disassembling the ion source, which is easy to maintain
1.7.4 Long-life electron multiplier
Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume GcmsQuantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume GcmsQuantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume Gcms
Specifications
Column oven
Furnace size 28×30×18cm
Operating temperature range RT +4ºC to 450ºC
Temperature setting accuracy 0.01ºC
Highest programmed heating rate 120ºC/min
Cooling speed 450ºC~50ºC less than 360s
Running time 999.99min
Column loss compensation dual channel
High-precision gas flow control module Available
Microchannel gas circuit integrated board Available
Proportional valve and pressure sensor Available
Temperature compensation ensures accurate flow Available
Hydrogen leakage protection function Available

Split/splitless capillary column injection port
High-precision electronic pressure/flow control Available
Maximum operating temperature 450ºC
Setting range of column head pressure 0~100psi
Accuracy of column head pressure control: 0.001psi
Setting range of total flow 0~1000ml/min(helium) ; 0~200ml/min (nitrogen)
Flow setting accuracy 0.001mL/min
Maximum split ratio 1:7500

Mass spectrometer detector
Mass number range 2~1200 amu
Maximum scanning speed 20,000 amu/s
Sensitivity EI Scan (helium): 1pg, octafluoronaphthalene OFN, m/z 272, S/N ≥2000
Resolution unit mass resolution
IDL (SIM) IDL ≤10 fg (100 fg, OFN, 8 consecutive injections, m/z272, peak area RSD <5%)
Quality stability ≤±0.1u/48 hours (constant temperature)
EI ion source Available
Ion source material Inert isothermal ceramic
Ionization energy 5~100eV (70eV during automatic tuning)
Ion source temperature Independent temperature control, 150~350ºC
Filament current 5~540μA (total emission current)
Dual filament design Available
GCMS interface temperature Capillary column is directly connected, 100~350ºC
Mass analyzer Equipped with pre-quadrupole high-precision all-metal quadrupole: The special design of the S-type pre-filter can completely eliminate photons and guide ions into the quadrupole without loss, which has strong anti-analyte pollution
Scan function Support full scan mode (Scan), selective ion scan mode (SIM)
In SIM mode, channel x group can be set arbitrarily
Detection system High-energy dynode under low voltage operation.Three-axis detector for long-life electron multiplier.Dynamic range: >5*106
Vacuum system Main pump: Edward turbomolecular pump 85 L/sec, 300L/sec optional. Auxiliary pump: 4 m3/h (low noise) over the vrd mechanical pump. The maximum column flow rate can reach 6.5mL/min (He). The standard is equipped with a primary vacuum gauge, and the software directly monitors the low vacuum degree

Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume Gcms
No accident shipping term:
DHL: 5-7 working days;
UPS: 7-9 working days;
FedEx: 7-9 working days;
EMS: 25-30 working days;
China Post: Depends on ship to which country;
Sea: Depends on ship to which country
Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume GcmsQ1: Are you trading company or manufacturer ?
A: We are manufacturer and do both OEM and ODM. We have our own R&D team.
Q2: How to order?
A: Send inquiries → Reply you quotations → Discuss details → Confirm samples → 
Deposit → Mass production → Cargo ready → Balance/Delivery → More cooperations.
Q3: What is your payment method ?
A: We accept T/T, Western Union, Paypal and MoneyGram, those depend on specific cases.
Q4: How long is your delivery time?
A: Usually 1-3 working days for products in stock. If we do special offer, it usually takes 
4-6 weeks. Also delivery time is according to your quantity of order.
Q5: How to transport?
A: DHL, UPS, FedEx, TNT, EMS, China Post and Sea are available.Also other shipping ways are 
available. Please feel free to contact us for other shipping ways.
Q6: How is your warranty service?
A: We do strict test before shipping and guarantee for 365 days. If quality problem you 
could send us pictures or video clips about problem. Then we deal with the problem ASAP.

Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume GCMS

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume Gcms pictures & photos
Quantitative Formic Acid Acetonitrile Ethanol Pyrolyse Perfume Gcms
US $77,885 / Piece
Min. Order: 1 Piece
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Trading Company
Number of Employees
10
Year of Establishment
2015-08-05